1
/
of
11
Siemens SIRIUS 3RV1031-4GA10 circuit breaker size S2 for motor protection
Siemens SIRIUS 3RV1031-4GA10 circuit breaker size S2 for motor protection
Regular price
$129.99 USD
Regular price
Sale price
$129.99 USD
Unit price
/
per
Taxes included.
Shipping calculated at checkout.
Free Shipping to USA on orders under 50 lbs.
Couldn't load pickup availability
Circuit breaker size S2 for motor protection, Class 10 A-release 36...45 A
Short-circuit release 585 A Screw terminal Standard switching capacity !!!
Phased-out product !!! Successor is SIRIUS 3RV2 Preferred successor
type is >>3RV2031-4VA10<<
product brand name SIRIUS
product designation circuit breaker
design of the product for motor protection
General technical data
product extension auxiliary switch Yes
power loss [W] for rated value of the current
● at AC in hot operating state 29 W
● at AC in hot operating state per pole 9.7 W
surge voltage resistance rated value 6 000 V
protection class IP on the front IP20
shock resistance 25g / 11 ms
mechanical service life (switching cycles) of the main
contacts typical
50 000
continuous current rated value 45 A
Substance Prohibitance (Date) 01.07.2006 00:00:00
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
ambient temperature
● during operation -20 ... +60 °C
● during storage -50 ... +80 °C
● during transport -50 ... +80 °C
Main circuit
number of poles for main current circuit 3
adjustable current response value current of the
current-dependent overload release
36 ... 45 A
operating voltage
● rated value 690 V
● at AC-3 rated value maximum 690 V
operational current at AC-3 at 400 V rated value 45 A
operating power at AC-3
● at 400 V rated value 22 kW
operating frequency at AC-3 maximum 15 1/h
Auxiliary circuit
number of CO contacts for auxiliary contacts 0
Protective and monitoring functions
product function
● ground fault detection No
● phase failure detection Yes
Subject to change without notice
© Copyright Siemens 7.28.2021 3RV10314GA10
Page 1/4
trip class CLASS 10
breaking capacity maximum short-circuit current (Icu)
● at AC at 240 V rated value 100 kA
● at AC at 400 V rated value 50 kA
● at AC at 500 V rated value 10 kA
● at AC at 690 V rated value 4 kA
Short-circuit protection
design of the overcurrent release and short-circuit
release
thermomagnetic
Installation/ mounting/ dimensions
mounting position any
fastening method screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 50022
height 140 mm
width 55 mm
depth 149 mm
required spacing with side-by-side mounting
● backwards 0 mm
● at the side 0 mm
Connections/ Terminals
product component removable terminal for auxiliary and
control circuit
No
type of electrical connection
● for main current circuit screw-type terminals with box terminals
● for auxiliary and control circuit screw-type terminals
arrangement of electrical connectors for main current
circuit
front side
type of connectable conductor cross-sections
● for main contacts
— solid 2x (0.75 ... 16 mm²)
— stranded 2x (0.75 ... 25 mm²), 1x (0.75 … 35 mm²)
— finely stranded with core end processing 2x (0.75 ... 16 mm²), 0.75 ... 25 mm²
● at AWG cables for main contacts 2x (18 ... 2), 1x (18 ... 2)
Safety related data
touch protection against electrical shock finger-safe